Sprache: DeutschSprache: Englisch

METAGLAS® Type 89 Sight Glass for Sanitary Clamp Fitting

for clamp fittings to DIN32 676 / ISO 2852

METAGLAS® Sight Glass Type 89

Applications

  • For clamp fittings to DIN32 676 / ISO 2852

Advantages

  • Extremely compact construction
  • Suitable for food processing & other
    sterile applications
  • Reliability against total failure – the possi-
    bility of sudden unexpected rupture is
    totally excluded
  • Fast & simple installation & maintenance
  • Extreme resistance to impact and temperature
  • Wide acceptance in the European & American
    food, beverage, pharmaceutical and
    chemical industries
  • Large view

Approvals and technical data
Manufactured and tested in conformance with:

  • Pressure Equipment Directive 2014/68/EU,
    Module H (DIN/EN/ISO 9001)
  • AD 2000 Standards W0/TRD 100
  • Sight glass fused to metal conforming to DIN 7079
  • Borosilicate glass to DIN 7080 / DIN 7079

Material certificates

  • Certificate of Conformity to EN 10204-3.1 or 3.2

Operating conditions

  • Pressure: -1 to 16 bar
  • Temperature: see table

Ring materials

Operating temperature

1.4462

-30°C to +280°C

2.4610

-60°C to +300°C


Nominal size

 


d1


d2


d3


d4


d5


S


S1


D

max. operating pressure [bar]

DN

Inch

 

 

 

 

 

 

 

 

 

25/32/40

1", 1½"

  50,5

38

33

43,5

  34,8

22

10

  65

16

  50

2"

  64 

51

45

56,5

  47,5

24

12

  85

16

  65

3"

  91

76

65

83,5

  72

34

19

125

16

100

4"

119

101

83

110,0

  97,4

36

19

160

16

 

5"

144,5

127

95

134,5

123

36

18

180

10

 

6"

167

153

110

156,5

146,8

36

19

210

10

 

8"

217,5

202

140

207,4

198

40

20

280

10